Manufacturer: | SEFRAM |
Illumination: | yes |
Operating temperature: | -10...50°C |
Related items: | 5790D |
Related items: | 5793D |
Related items: | 5794D |
Related items: | 5795D |
Related items: | 5797D |
Related items: | BKP60 |
Related items: | EX871515 |
Related items: | EX881602 |
Related items: | EX881603 |
Related items: | EX881605 |
Related items: | PKT-PTA |
Related items: | PKT-PTF-10 |
Related items: | PKT-PTF-20 |
Related items: | PKT-PTF-25 |
Related items: | PKT-PTF-30 |
Related items: | PKT-PTF-40 |
Related items: | PKT-PTF-50 |
Related items: | PKT-PTF-55 |
Related items: | PKT-PTF-56 |
Related items: | PKT-PTF-60 |
Related items: | SE027 |
Related items: | SE028 |
Related items: | SE029 |
Related items: | SE030 |
Related items: | SE031 |
Related items: | SE059 |
Related items: | SE060 |
Related items: | SE061 |
Related items: | SE062 |
Related items: | SE001 |
Related items: | SE002 |
Related items: | SE003 |
Related items: | SE004 |
Related items: | SE000 |
Related items: | TESTO-06020393 |
Related items: | TESTO-06020645 |
Related items: | TESTO-06024592 |
Related items: | TESTO-06024892 |
Related items: | TESTO-06280020 |
Related items: | TESTO-06281292 |
Related items: | TESTO-06287533 |
Related items: | TP200 |
Related items: | TP400 |
Related items: | TP870 |
Related items: | TP873 |
Related items: | TP873-5M |
Related items: | TP882 |
Related items: | TP-111 |
Related items: | TP-112 |
Related items: | TP-02 |
Related items: | TP-03 |
Related items: | TP-04 |
Related items: | TP-06 |
Related items: | TP-08 |
Related items: | TP-09 |
Related items: | TPK-59 |
Related items: | TPK-62 |
Related items: | UTT10K |
Related items: | UTT12 |
Conform to the norm: | CAT III 1000V |
Conform to the norm: | CAT IV 600V |
Conform to the norm: | EN 61010 |
Standard equipment: | test leads |
Standard equipment: | user's manual |
Measuring instrument features: | HOLD function |
Measuring instrument features: | MIN/MAX function |
Type of meter: | digital multimeter |
Weight with battery: | 460g |
Continuity test: | acoustic indication |
Sampling: | 3x/s |
Temperature measuring range: | -40...400°C |
True effective value measurement: | True RMS AC+DC |
Bargraph: | yes |
Measurement: | AC current |
Measurement: | AC voltage |
Measurement: | capacitance |
Measurement: | continuity |
Measurement: | DC current |
Measurement: | DC voltage |
Measurement: | frequency |
Measurement: | resistance |
Measurement: | temperature (external probe required) |
Dimensions (W x H x D): | 94x190x48mm |
AC current measuring range: | 60mA |
AC current measuring range: | 600mA |
AC current measuring range: | 6A |
AC current measuring range: | 10A |
Resistance measuring range: | 600Ω...40MΩ |
DC current measuring range: | 60mA |
DC current measuring range: | 600mA |
DC current measuring range: | 6A |
DC current measuring range: | 10A |
DC voltage measuring range: | 60mV |
DC voltage measuring range: | 600V |
AC voltage measuring range: | 60mV |
AC voltage measuring range: | 1kV |
Frequency measuring range: | 100Hz...100kHz |
Capacitance measuring range: | 1µF...10mF |
Diode test: | 0.4mA |
Battery/ rechargeable battery: | battery 6LR61 9V x1 |
Display parameters: | 3,75 digit (6000) |
Frequency measuring accuracy: | ±(0.1%+2 digit) |
Capacitance measuring accuracy: | ±(1.2%+ 2 digit) |
AC current measuring accuracy: | ±(1.2% + 3 digit) |
DC voltage measuring accuracy: | ±(0.08% + 2 digit) |
DC current measuring accuracy: | ±(0.8% + 3 digit) |
AC voltage measuring accuracy: | ±(0.8% + 5 digit) |
Resistance measuring accuracy: | ±(0.8%+2 digit) |
Temperature measurement accuracy: | ±(1% + 10 digit) |
Kind of display used: | LCD |
Power supply: | battery 6LR61 9V x1 |