Manufacturer: | FLUKE |
Type of meter: | multifunction |
Interface: | Bluetooth |
Measurement: | AC current |
Measurement: | AC voltage |
Measurement: | capacitance |
Measurement: | DC current |
Measurement: | DC voltage |
Measurement: | frequency |
Measurement: | inrush current |
Measurement: | resistance |
Max. diameter of measured cable: | 34mm |
Kind of display used: | LCD |
DC voltage measuring range: | 600V |
DC voltage measuring range: | 1kV |
DC voltage measuring accuracy: | ±(1% + 5 digit) |
AC voltage measuring range: | 600V |
AC voltage measuring range: | 1kV |
AC voltage measuring accuracy: | ±(1.5% + 5 digit) |
DC current measuring range: | 100mA...999.9A |
DC current measuring accuracy: | ±(2% + 5 digit) |
AC current measuring range: | 100mA...999.9A |
AC current measuring accuracy: | ±(2% + 5 digit) |
True effective value measurement: | True RMS |
Resistance measuring range: | 600Ω |
Resistance measuring range: | 6kΩ |
Resistance measuring range: | 60kΩ |
Capacitance measuring range: | 0.1...100µF |
Capacitance measuring range: | 1mF |
Capacitance measuring accuracy: | ±(1%+ 4 digit) |
Frequency measuring range: | 5...500Hz |
Frequency measuring accuracy: | ±(0.5%+5 digit) |
Resistance measuring accuracy: | ±(1%+5 digit) |
Test: | diodes |
Continuity test: | acoustic indication |
Continuity test: | |
Pollution degree: | 2 |
Dimensions: | 274x86x47mm |
Weight with battery: | 463g |
Power supply: | battery LR6 AA 1,5V x2 |
Standard equipment: | case |
Standard equipment: | crocodile clip FLK-AC285 |
Standard equipment: | FLK-I2500-18 flexible current probe |
Standard equipment: | magnetic hanging strap FLK-TOOLPAK |
Standard equipment: | test leads FLK-TL-224 |
Standard equipment: | test probes TP175 |
Conform to the norm: | CAT III 1000V |
Conform to the norm: | CAT IV 600V |
Conform to the norm: | EN 61010 |
Measuring instrument features: | automatic power-off |
Measuring instrument features: | contactless voltage measurement |
Measuring instrument features: | flexible current probe up to 2500A |
Measuring instrument features: | HOLD function |
Measuring instrument features: | low battery indicator |
Measuring instrument features: | MIN/MAX/MEDIUM function |
Measuring instrument features: | power quality indicator shows whether a problem is in the equipment or the power line |
Measuring instrument features: | transfer measurement data wireless |
Battery/ rechargeable battery: | battery LR6 AA 1,5V x2 |
Software: | Fluke Connect |
Illumination: | yes |
Kind of meter: | digital |
Kind of meter: | pincers type |
CF crest factor: | 1.42 @ 1kA |
CF crest factor: | 2.5 @ 600A |
CF crest factor: | 3 @ 500A |