Manufacturer: | OWON |
Type of meter: | benchtop multimeter |
Interface: | LAN |
Interface: | RS232 |
Interface: | USB |
Kind of display used: | LCD 4" |
Standard equipment: | 2 crocodile clips |
Standard equipment: | fuse |
Standard equipment: | mains cable |
Standard equipment: | test leads ( 2pcs.) |
Standard equipment: | USB cable |
Measuring instrument features: | data visualization Min, Max, live, historical data and trending charts |
Measuring instrument features: | MIN/MAX/AVG function |
Measuring instrument features: | operates with thermocouple types: J, K, T, E, R, S, B, N |
Measuring instrument features: | Pass/Fail function |
Measurement: | AC current |
Measurement: | AC voltage |
Measurement: | capacitance |
Measurement: | continuity |
Measurement: | DC current |
Measurement: | DC voltage |
Measurement: | frequency |
Measurement: | resistance (2-wire) |
Measurement: | resistance (4-wire) |
Measurement: | temperature |
Dimensions (W x H x D): | 235x110x295mm |
Display parameters: | 5,5 digit |
Continuity test: | |
Sampling: | 150x/s |
True effective value measurement: | True RMS AC |
AC current measuring range: | 20mA |
AC current measuring range: | 200mA |
AC current measuring range: | 2A |
AC current measuring range: | 10A |
Resistance measuring range: | 200Ω |
Resistance measuring range: | 2kΩ |
Resistance measuring range: | 20kΩ |
Resistance measuring range: | 200kΩ |
Resistance measuring range: | 2MΩ |
Resistance measuring range: | 10MΩ |
Resistance measuring range: | 100MΩ |
DC current measuring range: | 0.2mA |
DC current measuring range: | 2mA |
DC current measuring range: | 20mA |
DC current measuring range: | 200mA |
DC current measuring range: | 2A |
DC current measuring range: | 10A |
DC voltage measuring range: | 200mV |
DC voltage measuring range: | 2V |
DC voltage measuring range: | 20V |
DC voltage measuring range: | 200V |
DC voltage measuring range: | 1kV |
AC voltage measuring range: | 200mV |
AC voltage measuring range: | 2V |
AC voltage measuring range: | 20V |
AC voltage measuring range: | 200V |
AC voltage measuring range: | 750V |
Frequency measuring range: | 20...1MHz |
Capacitance measuring range: | 2nF |
Capacitance measuring range: | 20nF |
Capacitance measuring range: | 200nF |
Capacitance measuring range: | 2µF |
Capacitance measuring range: | 200µF |
Capacitance measuring range: | 10mF |
Diode test: | 2V |
Frequency measuring accuracy: | ±(0.01% + 0.003% range) |
Capacitance measuring accuracy: | ±(1%+ 0.5% range) |
AC current measuring accuracy: | ±(0.5% + 0.1% range) |
DC voltage measuring accuracy: | ±(0.015% + 0.004% range) |
DC current measuring accuracy: | ±(0.055% + 0.005% range) |
AC voltage measuring accuracy: | ±(0.2% + 0.05% range) |
Resistance measuring accuracy: | ±(0.02%+0.003% range) |
Supply voltage: | 90...240V AC |
Conform to the norm: | CAT II 600V |
Conform to the norm: | CAT II 1000V |
Conform to the norm: | EN 61010 |