Описание товара
ultra slim design with 105 mm (6SU) width
universal input 85 ~ 264 VAC (277 VAC operational)
no load power consumption isolation class II
DC output voltage adjustable
protections: short circuit / overload / over voltage
cooling by free air convection
DIN rail TS-35/7.5 or 15 mountable
over voltage category III
LED indicator for power on
3 years warranty
applications:
household control system
building automation
industrial control system
factory automation
electro-mechanical apparatus
[b]for professional use only[/b]
This device must be installed by a qualified person.
output:
DC voltage: 12 V
rated current:
115 VAC (rated current): 10.2 A
230 VAC (rated current): 11.3 A
rated power:
115 VAC (rated power): 122.4 W
230 VAC (rated power): 135.6 W
ripple & noise (max.): 100 mVp-p
voltage adj. range: 10.8 - 13.8 V
voltage tolerance: ± 2.0 %
line regulation: ± 1.0 %
load regulation: ± 1.0 %
setup, rise time: 500 ms, 60 ms / 230 VAC - 500 ms, 60 ms / 115 VAC at full load
hold up time (typ.): 30 ms / 230 VAC - 12 ms / 115 VAC at full load
input:
voltage range: 85-264 VAC (277 VAC operational) - 120-370 VDC (390 VDC operational)
frequency range: 47 - 63 Hz
efficiency (typ.): 89 %
ac current (typ.): 3 A / 115 VAC - 70 A / 230 VAC
inrush current (typ.): cold start 35 A / 115 VAC - 70 A / 230 VAC
protection:
overload:
105 - 135 % rated output power
protection type: constant current limiting withing 50% ~ 100% rated output voltage, recovers automatically after fault condition is removed
hiccup mode when output voltage overvoltage:
14.2 ~ 16.2 V
protection type: shut down output voltage, re-power on to recover
environment:
working temperature: -30 to +70 °C
working humidity: 20 to 90 % RH non-condensing
storage: -40 to +85 °C, 10 to 95% RH non-condensing
temperature coefficient: ± 0.03 %/°C (0 - 45°C ) RH non-condensing
vibration: 10 - 500 Hz, 2G 10 min / 1 cycle, 60 min each along X, Y, Z axes; mounting: compliance to IEC60068-2-6
operating altitude: 2000 m
over voltage category: III, according to EN62368, EN61558, EN50178, EN60664-1, EN62477-1, altitude up to 2000 meters
safety & EMC:
safety standards: IEC62368-1, UL62368-1, UL61010, TUV EN61558-2-16, EACTPTC004 approved; design refer to EN50178, TUV EN62368-1
withstand voltage: input to output: 4 kVAC
isolation resistance: input to output: 100 MOhm / 500 VDC / 25 °C / 70 % RH
EMC emission:
conducted (EMC emission): EN55032 (CISPR32) / Class B
radiated: EN55032 (CISPR32) / Class B
harmonic current: EN61000-3-2 / Class A
voltage flicker: EN61000-3-3
EMC immunity:
ESD: EN61000-4-2 / Level 3, 8KV air - Level 2, 4KV contact - criteria A
radiated susceptibility: EN61000-4-3 / Level 3 - criteria A
EFT/Burest: EN61000-4-4 / Level 3 - criteria A
surge: EN61000-4-5 / Level 4, 2KV/L-N - criteria A
conducted (EMC immunity): EN61000-4-6 / Level 3 - criteria A
magnetic field: EN61000-4-8 / Level 4, criteria A
voltage dips and interruptions: EN61000-4-11 / >95% dip 0.5 periods, 30% dip 25 periods - >95% interruptions 250 periods
other:
MTBF: 536 hrs min. MIL-HDBK-217F (25 °C)
dimensions: 105 x 90 x 54.5 mm (W x H x D)