ESR measurement range 0 to 40 Ohm
ESR resolution as low as 0.01 Ohm
capacitance range 1µF…22mF (22,000µF)
can also be used for low-Ohms resistance checking
built-in protection circuitry means risk of damage to the
unit due to residual charge is greatly reduced
integrated controlled discharge circuitry reduces the need
for the user to manually discharge capacitors before test
use in or out of circuit for ESR measurement
automatic and manual power-off
with audible alerts
user manual: English only
Product basic info
Primary colours: Purple
Additional colours: Black
Depth unit: 20 mm
Height unit: 70 mm
Width unit: 103 mm
Weight unit: 98 g
Technical data
Abuse voltage C Abuse voltage C > 10 microfarad: ± 50 V
Auto shut-off: Yes
Capacitance accuracy %: ± 4 %
Manual shut-off: Yes
Maximum peak test current into s/c: ± 25 mA
Minimum peak test current into s/c: ± 20 mA
Peak test voltage across o/s: 2.5-3 V
Capacitance accuracy µF: ± 0.2 µF
Environmental data
Operating temperature range: 10-35 °C
Operational properties
Auto-discharge voltage limit: ± 50 V
Inactivity power-down period: 30 s
ESR specifications:
- Measuring Range: 0 Ohm ~ 40 Ohm
- Resolution (ESR < 2 Ohm): 0.01 Ohm ~ 0.02 Ohm
- Resolution (ESR > 2 Ohm): 0.1 Ohm ~ 0.2 Ohm
- Accuracy (ESR < 2 Ohm): ± 1.5 % ± 0.02 Ohm
- Accuracy (ESR > 2 Ohm): ± 1.5 % ± 0.2 Ohm
- Abuse Voltage C < 10 µF ± 275 V; C > 10 µF ± 50 V
- Auto-Discharge Voltage Limit: ± 50 V
Audible alerts: Yes
Battery voltage rating range: 8.5-12 V
Capacitance measurement range: 1-22000 µF
Power supply
Batteries included: Yes
Battery required: Yes
Number of batteries: 1
Battery voltage rating: 12 V
Low battery indicator: Yes
Voltage warning threshold: 8.5 V
Battery composition: Alkaline
Battery IEC size: A23 (8LR932 ,1811A, 3LR50, 8LR23, 8LR932, AS23S, E23A, GP12A, GP23, GP23A, K23A, L1018, LR23A, MN21, MN23, P23GA, VR22, V23GA)
Included
Automatic discharge function: No
(EN)