ATLAS ZEN - ZENER DIODE ANALYSER (0 - 50 V)

106.03/ gab.Cena
ieskaitot PVN 21%
ID:1518975
Kods:ZEN50
EAN:5410329632564
Grupa:VellemanTest Equipment & Lab Power Supplies (EN)Measuring Equipment (EN)Electronic (EN)Component Analyzers (EN)
Ražotājs:Azo
Pieejamība piegādātāja noliktavā:
10
Piegādes laiks:14-21 darba dienas
Minimalālais daudzums:1
Produkta apraksts


test Zener diodes, Avalanche diodes, VDRs, TVSs, LED strings and much more (up to 50 V)

measures breakdown voltage (0.00 V to 50.00 V) with a resolution as fine as 20 mV

measures slope resistance (up to 1 kO at 15 mA with a 1O resolution)

supports most Zeners, Avalanche diodes and reference diodes from 0 V up to 50 V

great for testing VDRs, TVSs and other types of voltage protection devices

selectable test currents: 2 mA, 5 mA, 10 mA, 15 mA

tiny duty cycle of test current to minimise heating of your component, even when testing at 50 V and 15 mA

single alkaline AAA battery (incl.)

long battery life and regulated test conditions even when the battery voltage is as low as 1.0 V

continuous measurement display (updated 3 times per second)

hold-function to hold displayed values even if component is removed

fitted gold plated crocodile (alligator) clips

comprehensive printed user guide available (English - German - Italian)

specification summary at 20-25 °C (68-77 °F) unless otherwise specified

Zener voltage range (Vz): 0.0 V - 50.0 V

nominal test currents (Iz) : 2mA, 5mA, 10mA, 15mA

set test current accuracy: ± 1 % ± 0.2 mA

Zener voltage measurement accuracy: ± 1% ± 40 mV

Zener voltage measurement resolution : 20 mV - 40 mV

test frequency accuracy: -1.5% ~ +1.5%

60 V pulsed DC satisfies lower limit of 75 V(DC) for Low Voltage Directive 2006/95/EC

test current into a short circuit (pulsed) : 35 mA

test current duty cycle :

min: 0.1%

max: 5%

typical: 1%

duty cycle of test current designed to keep power dissipation of Zener under test to very low levels

maximum external voltage: ± 50 V

slope resistance measurement range:

Iz = 2 mA (slope resistance measurement range): 0-8000 Ohm

Iz = 5 mA (slope resistance measurement range): 0-3200 Ohm

Iz = 10 mA (slope resistance measurement range): 0-1600 Ohm

Iz = 15 mA (slope resistance measurement range): 0-1000 Ohm

displayed slope resistance resolution:

Iz = 2 mA (displayed slope resistance resolution): 5 Ohm

Iz = 5 mA (displayed slope resistance resolution): 2 Ohm

Iz = 10 mA (displayed slope resistance resolution): 1 Ohm

Iz = 15 mA (displayed slope resistance resolution): 1 Ohm

slope resistance measurement accuracy:

Iz = 2 mA (slope resistance measurement accuracy): ±1% ±10 Ohm

Iz = 5 mA (slope resistance measurement accuracy): ±1% ±4 Ohm

Iz = 10 mA (slope resistance measurement accuracy): ±1% ±2 Ohm

Iz = 15 mA (slope resistance measurement accuracy): ±1% ±2 Ohm

slope resistance current span: (Iz-50%) to (Iz+50%)

slope resistance measurement method :

differentiation of curve that fits:: (Iz-50%, Vz1), (Iz, Vz2), (Iz+50%, Vz3)

measurement rate: 3 Hz

auto-off period: 60 sec.

battery:

type: 1 x AAA alkaline

voltage range: 0.9 V - 1.6 V

low battery warning: 1.0 V ± 0.05 V

operating temperature: 10-40°C

dimensions (excl. leads): 103 x 70 x 20 mm

weight: 98 g

fundamental materials: plastic, glass and metal