Product basic info
Instruction manual languages: Dutch, English, French, German, Polish, Portuguese, Spanish
Primary colours: Red
Additional colours: Yellow
Depth unit: 35 mm
Height unit: 194 mm
Width unit: 72 mm
Weight unit: 230 g
Physical properties
Display height: 24 mm
Display width: 37 mm
LED light: Yes
Backlight: Yes
Maximum digits display: 3999
Electrical data
Capacitance specifications:
- 10 n/100 n/1 µ/10 µ/100 µ/1 m/10 m/100 mF
- accuracy:
- ± (4.0 % of rdg + 25 digits) for 10 nF range
- ± (4.0 % of rdg + 15 digits) for 100 nF - 100 µF range
- ± (5.0 % of rdg + 25 digits) for 1 mF - 100 mF range
- overload protection: 15 s max. 250 V (all ranges)
Overload protection: Yes
Maximum DC current: 600 A
AC current:
- 40/400/600 A (max. line voltage 240 V)
- basic accuracy:
- ± (2.5 % of rdg + 10 digits) for 40 A - 600 A range
AC voltage:
- 0.4/4/40/400/600 V
- basic accuracy:
- ± (1.0 % of rdg + 10 digits) for 0.4 V range
- ± (1.0 % of rdg + 5 digits) for 4 V - 400 V range
- ± (1.2 % of rdg + 5 digits) for 600 V range
- input impedance: 10 Mohm
- frequency range: 50 - 1000 Hz
- maximum input: 600 V
DC current:
- 40/400/600 A (max. line voltage 240 V)
- basic accuracy:
- ± (2.5 % of rdg + 10 digits) for 40 A ~ 600 A range
Continuity test: Yes
DC voltage:
- 0.4/4/40/400/600 V
- basic accuracy:
- ± (0.5 % of rdg + 3 digits) for 0.4 V range
- ± (0.8 % of rdg + 5 digits) for 4 V - 400 V range
- ± (1.0 % of rdg + 5 digits) for 600 V range
- input impedance: 10 Mohm
- maximum input: 600 V
Diode test: Yes
Duty cycle:
- 0.5 - 99 % @ pulse width of 100 µs to 100 ms
Frequency:
- 10 Hz/100 Hz/1 KHz/10 KHz/100 KHz/1 MHz/10 MHz
- basic accuracy:
- ± (0.5 % of rdg + 2 digits) for 10 Hz - 10 MHz range
- overload protection: 15 s max. 250 V (all ranges)
True rms: No
AC current measurements: 40 A, 400 A, 600 A
AC voltage measurements: 4 V, 40 V, 400 mV, 400 V, 600 V
Capacity measurements: 1 µF, 1 mF, 10 µF, 10 mF, 10 nF, 100 µF, 100 mF, 100 nF
DC current measurements: 40 A, 400 A, 600 A
DC voltage measurements: 4 V, 40 V, 400 mV, 400 V, 600 V
Frequency measurements: 1 MHz, 10 Hz, 10 kHz, 10 MHz, 100 Hz, 100 kHz, 1000 Hz
Duty cycle measurements: 0.5-99 %
Resistance measurements: 4 kΩ, 4 MΩ, 40 kΩ, 40 MΩ, 400 kΩ, 400 Ω
Resistance specifications:
- 400/4 K/40 K/400 K/4 M/ 40 Mohm
- basic accuracy:
- ± (1.0 % of rdg + 10 digits) for 400 ohm range
- ± (0.8 % of rdg + 5 digits) for 4 K - 4 Mohm range
- ± (2.0 % of rdg + 10 digits) for 40 Mohm range
- overload protection: 15 s max. 250 V (all ranges)
Maximum AC current: 600 A
Technical data
Safety standard: EN 61010-1
Safety rating: Cat III / 600 V
Automatic power-off function: Yes
Pollution degree: 2
Data-hold function: Yes
Set-up options
Alarm sound type: Buzzer
Environmental data
Temperature specifications:
- -20 °C - 1000 °C
- basic accuracy:
- ± (5 % of rdg + 4 °C) for -20 °C to 0 °C range
- ± (2 % of rdg + 3 °C) for 0 °C to 400 °C range
- ± (3 % of rdg + 3 °C) for 400 °C to 1000 °C range
- overload protection: 15 s max. 250 V
Power supply
Battery required: Yes
Number of batteries: 3
Input voltage rating VAC range: 0-600 V
Battery operated: Yes
Battery voltage rating: 4.5 V
Input voltage rating VDC range: 0-600 V
Low battery indicator: Yes
Battery composition: Alkaline
Battery IEC size: AAA (LR03, R03, FR03, HR03, KR03, ZR03 ,24A, 24D, 24LF, UM4, Micro, MN2400, MX2400, MV2400)
(EN)